Description
- Overview:
- RE-2554 fire alarm control panel is designed with unique protocol to be used for small & medium establishments, Schools, hospitals, hotels, banks, commercial building, and small scale industries. The system is user friendly with includes all standard to ensure ease for use and high reliability.
- Features:
-
- witched Mode Power Supply.
- Modular Construction
- Auto Resettable Fuse
- Surge Protection for all Input and outputs.
- Programmable AC loss delay/Trouble Remainder/Alarm Verification
- Battery polarity reversible protection
- Surface Mount Technology
- Over All current consumption is low.
- Fully complies with UL -864 and NFPA-72.
- Rugged CRCA sheet with powder coated finish.
- Operates on 110 – 220v 50 /60 Hz, AC Mains power supply.
- 16×2 Dot Matrix LCD Display.
- 4/8 Class B Style ‘B ‘ or Style ’C’ initiating device circuit (IDC).
- All zones accept smoke detectors and any normally open contact device.
- Any Zone can be configured as Alarm or supervisory Zone.
- 2ClassBNotificationApplianceCircuits(NAC).
- NAC shall be programmed as silenceable or Non Silenceable.
- Supervisory Zone shall be Latching or Resettable.
- Standby (battery) backup 24v DC power supply with built in charger
- Error free Fire / Fault status in unambiguous colored LED indication.
- System ON indication.
- Main, Standby status audible and visual indication.
- Battery Low visual warning with audible tone.
- FormC relays for fire, fault and supervisory.
- Resettable / Steady 24V D.C. Output.
- RS 485 Communication facility (Optional).
- Lamp Test facility.
- All field wiring circuits are Power limited except 110 – 220v AC and Battery.
- All field wiring circuits are supervised.
- Walk Test facility.
- Zone Isolation facility with loop voltage cut off.
- Earth fault annunciation facility at 0 ohms.
- AC Low voltage cutoff.
- Programmable AC loss delay.
- Programmable Alarm verification.
- Programmable Trouble reminder.
- Technical Specification:
- Primary Power
120 – 220VAC ± 10%, 50 Hz, 2.5Amps. - Standby Power
24V D.C (2 Nos of 12v, 12Ah Sealed Lead acid battery).
Quiescent current: 120mA. - Operating Condition
Operating Temperature 0 – 49° C/32-120° F.
Relative Humidity 93 ± 2% RH (non- condensing) at 32 ±2° C/90 ±3° F. - Charging Circuit
Charging Voltage 28.2V, ±0.5V
Charging Current 800mA (Max.). - Common Relays
Type : Form C
No of Relays : 3
Relay Contact Rating : 2Amps @ 30 VDC,
0.5Amps @ 125VAC.
Power Factor : 1.0
Dimensions : (440W X 340H X 120D)